UEN 3137
Year of Manufacture: 2002
Year Commissioned: Standby Boiler Dual Fuelled – Natural Gas & Oil Condition: Excellent Operating Hours: Low Status: In Storage |
|
Used as standby boiler – Low hours and excellent condition
Dual Fuelled – Natural Gas & Oil
Superheater Outlet Pressure: 15 bar
Superheater Outlet Temp: 235 Deg C
Boiler Working Pressure: 16 bar
Boiler Design Pressure: 17 bar
Hydraulic Test Pressure: 15.5 bar
Type of Combustion Equipment: Gas Register / Oil Atomising
Combustion Control: Fully Automatic Modulating
Fuel: Natural Gas & Light Fuel Oil
Electrical Supply: 400 V 3 Phase 50Hz 4 wire AC
Control Voltage: 200 / 110 V
Overall Approximate Dimensions:
Length – 10,000mm
Width – 6,500mm
Height – 6,560mm
Weight Empty – 89,000kg
Scope of Supply:
Boiler transmitters blow down valves etc.
Switch cabinets
Boiler supports x 2
Various gas pipes
Vent pipe
Sample cooler
FD Fans x 2 & staging
Flow meters
Burner control panel.
Further Information available by request – NDA will apply