106MW HFO Fuelled CHP Power Plant

Category
Other, Power Plant - Types
About This Product

UEN 3267

Size: 106 MWe HFO Fuelled Power Plant

Year Commissioned:

Condition:

Operating Hours:

Status:

2000

Used – Excellent

~65,000

Dismantled and Stored

Manufacturer : Wartsila

Manufacturer’s type: 7 x 18V46 HFO

Made in year: 2000

Capacity : 106 MW

Power factor: 0.8

Efficiency : 0.97 (at rated output, 50 Hz and power factor 0.8)

Application: Base Load Power Generation

Engine type: 18V46 HFO

Engine rated ISO output : 17.55 kWm

Specific fuel consumption : 200 grams @ fuel LCV of 9800 kcal/Kg

Alternator type : ABB AMG 1600 SS12 DSEB

Alternator output: 20000 kVA, 11 kV, 50 Hz

Generator transformers (4 No.s) : BHEL 40 000 kVA, 110 / 11 kV

Lube oil separators (7 No.s) : Alfa Laval LOPX 710 SFD 34

Fuel oil separators (4 No.s) : Alfa Laval FOPX 614 TFD 24

Waste heat recovery boilers (3 No.s) : Alborg 4270 kg/h at 7 bar

Complete balance of plant included in scope.